UPS Online Double Conversion Transformer Based HT4000T(10~30KVA)

LCD display to show input and output voltage, load, frequency, inside temperature of the device,battery charge load

Protection: short circuits, high and low voltages, overload, reverse connection of batteries and High charge, etc.

Connecting to parallel card & isolated transformer in the bypass section

Communication with PC by RS232 (standard), USB / RS485 / SNMP / Dry Call (optional)

Category:

Description

 

Online Double Conversion, transformer base technology with stable and uninterrupted power and complete sine waveform linear and non-linear loads at maximum load consumption

Output Power factor of 0.8 & Input power factor 0.99 and Active Power Factor Correction (Apfc)

Select current charging : 2A / 4A / 6A / 8A / 10A / 12A

Overload capacity up to 105% ~ 125% for 10 min , 125% ~ 150% for 1 min ,150%~200% for 200 ms ,Up to200%for 100 ms

wide input frequency range for operation with variety of generators in the range of 40 to 70 Hz and proper stabilization of the output frequency of 50 Hz with a telorance of 0.1

LCD display to show input and output voltage, load, frequency, inside temperature of the device,battery charge load

Protection: short circuits, high and low voltages, overload, reverse connection of batteries and High charge, etc.

Connecting to parallel card

Communication with PC by RS232 (standard), USB / RS485 / SNMP / Dry Call (optional)

Adjusting the output voltage ,EOD, automatic start, bypass mode and adjusting the frequency and ECO MODE through the LCD display panel

Adjusting the output frequency at 50 and 60 Hz and having Auto frequency Sensing

Cold Start and automatic start-up after connecting the city electricity and having settable delay

DSP (digital signal processors )control technology Effective software and hardware protection

Shut down automatically in emergency time (EPO)

<!doctype html public “-//w3c//dtd xhtml 1.0 transitional//en” “http://www.w3.org/tr/xhtml1/dtd/xhtml1-transitional.dtd”>

 

 

<![if supportMisalignedColumns]><![endif]>

 

Swipe left on mobile

MODEL HT4100T HT4150T HT4200T HT4300T
POWER VA 10000 15000 20000 30000
W 8000 12000 16000 24000
INPUT Rated voltage 380/ 400/415 V
Voltage range ± 25%
Rated frequency 50 Hz / 60 Hz
Frequency range 40 ~ 70Hz
Bypass voltage range ± 5% Hz
Voltage rang bypass ± 25 V
OUTPUT voltage 220 / 230 / 240  (1ᶲ+N+PE)
Voltage precision ±1%
Frequency  50/60 ± 0.1 Hz in battery mode
Rated frequency 50 Hz/ 60 Hz (settable)
Power factor i0.8
Crest factor 3˸1
THDV ≤ 2% (linear load) ≤ 5% (non-linear load)
Waveform Sinusoidal
Overload   105% ~ 125% for 10 min , 125% ~ 150% for 1 min ,150%~100% for 200 ms , 200%for 100 ms
BATTERIES Dc Voltage 192 Vdc
Charging current Default 8A (2A/4A/6A/8A/10A/12A selectable)
Number of battery 12V x 16 pcs
Charging  voltage 216 Vdc
EOD 168 Vdc
SYSTEM Protections Short circuit, overload , overvoltage undervoltage , low battery, over temperature
Communications RS232 / USB (standard) RS485 / SNMP / dry contacts (optional)
OTHERS Operaring temperature 0°C~ 40°C
Relative humidity 0~95% (non-condensing)
altitude ≤1000m (derating 1% for each additional 100 m)
IP rating IP 20
Noise level < 60 dB (at 1m)
Transfer time 0 ms
PHYSICAL Dimensions (W x D x H) (mm) 315 x 600 x 900 400 x 815 x 1100
Packaged dimensions
(WxDxH) (mm)
435 x 700 x 1100 525 x 925 x 1305
Net weight (kg) 140 210 240 280
Gross werghi (kg) 153 226 255 295

 

 