UPS Online Double Conversion Modular 3phase/3phase MJ(80~160KVA)
With extendable capacity up to 160KVA/160KW in each closet and full DSP control technology, is the third generation of three-phase high-frequency modular UPS. All internal modules (power module, charger module, and monitor module ) are modularly designed and hot-swappable. In addition, they are constructed with small modules, assuring both system compactness and reliability.
Description
UPS HT-MJ Series With extendable capacity up to 160KVA/160KW in each closet and full DSP control technology is the third generation of three phase high-frequency modular UPS. All internal modules (power module, charger module, and monitor module ) are modularly designed and hot-swappable. In addition, they are constructed with small modules, assuring both system compactness and reliability. Its full isolation design between fragile components and air flue makes the best of combination of reliability, functionality and flexibility. Moreover, this system adopts advanced “N+X” wireless parallel and redundancy technology, avoiding single-point failure, and further strengthening the reliability.
High frequency online double—conversion with DSP control
Hot-swappable operation for all modules
Inbuilt integrated PDU system, easy installation, and economic initial investment
Wide input voltage range, 50Hz/ 60Hz auto-sensing frequency
Support two modes of frequency conversion: 50Hz input/60Hz output and 60Hz input / 50Hzoutput
Advanced “N+X’ wireless parallel and redundancy technology easily set up different numbers of redundancy UPS module via LCD
The share battery pack in parallel operation, saving user’s battery cost
System capacity up to 160KVA/160KW constructed by each module 20KVA / 20KW, single charger module be equipped with 30 A
Charging current,4 modules are configured maximally
Flexible charger parameter and battery configuration setting, selectable battery number: 32 pcs /34 pcs/36pcs/38 pcs/40 pcs
Advanced intelligent battery management techniques, prolong the working life of the battery effectively
Support battery cold start and mains auto restart
Complete isolation between key components and air duct effectively improve the system reliability
Fragile components can be replaced easily as modules at a low maintenance cost
Front accessible maintenance, top/bottom cable entry compatible
Perfect protection for hardware and software (C class lighting protection, circuit breaker, fuse, software, and hardware protection)
Robust self-detection, abundant event log for future check
5.7 inches LCD touch screen, friendly human-machine interaction
Standard emergency power off (EPO)
Standard RS232/USB/RS485/dry contacts communication port
Optional SNMP communication port
Inbuilt battery module available, 40 x 12V/9AH for each module
Swipe left on mobile
<!doctype html public “-//w3c//dtd xhtml 1.0 transitional//en” “http://www.w3.org/tr/xhtml1/dtd/xhtml1-transitional.dtd”>
<![if supportMisalignedColumns]><![endif]>
MODEL | MJ 80 | MJ 160 | |||||||
POWER | KVA | 80 KVA | 160 KVA | ||||||
KW | 80 KW | 160 KW | |||||||
Numbers of parallel module | 1~4 | 1~8 | |||||||
Numbers of redundancy module | 0~3 | 0~7 | |||||||
UPS power module | 20 KVA/ 20 KW | ||||||||
Input | Rated Voltage | 380 V/ 400 V/ 415 V | |||||||
Voltage range | 204 ~ 242 V (load ≤ 50%) | ||||||||
242 ~ 277 V (50% < load ≤ 70%) | |||||||||
277V ~ 520 V(70% < load ≤100%) | |||||||||
Rated frequency | 50 / 60 Hz (auto-sense) | ||||||||
frequency range | 40 ~ 70 Hz | ||||||||
Power factor | ≥ 0.99 | ||||||||
Total harmonic distortion (THDI) | ≤ 3% | ||||||||
Bypass voltage range | Rated output voltage -40%~rated output voltage +20% (settable via LCD) | ||||||||
OUTPUT | Voltage | 380 V/ 400 V/ 415 V | |||||||
Voltage rengulation | ± 1% | ||||||||
Frequency | Synchronized with utility in mains mode | ||||||||
50/60 Hz ± 0.1% in battery mode | |||||||||
Power factor | 1. 0 | ||||||||
Waveform | Pure sine wave | ||||||||
Crest factor | 3:–1 | ||||||||
Total harmonic distortion (THDV) | ≤ 1% (linear load); ≤ 5% (non-linear load) | ||||||||
Transfer time | 0 ms | ||||||||
Inverter overload capability | 110% ~130%: transfer to bypass in 10 mins | ||||||||
130% ~ 150%: transfer to bypass in 1 min | |||||||||
> 150%: transfer to bypass in 0.5 s | |||||||||
Bypass overload capability | ≤150%: long time running | ||||||||
> 150%: power off in10 s | |||||||||
BATTERIES | DC voltage | ± 240 vdc (options : ± 192 vdc/± 240 vdc/± 216 vdc/ ± 228 vdc/) | |||||||
Inbuilt battery of standard model | 40 x 12 V / 9 Ah for each module | ||||||||
Charging current | 1 ~30 A / 60 A (settable via LCD) | ||||||||
SYSTEM | Efficiency | ≥ 94% | |||||||
Display panel | 5.7 Inches LCD touch screen | ||||||||
Alarm | battery mode, low battery , fans fault etc | ||||||||
EMI | EN62040-2 | ||||||||
EMS | IEC61000-4-2 (ESD) | ||||||||
IEC61000-4-3 (RS) | |||||||||
IEC61000-4-4 (EFT) | |||||||||
IEC61000-4-5 (surge) | |||||||||
OTHERS | Humidity | 0 ~ 95% RH @ 0 ~ 40°C (non-condensing) | |||||||
Noise level | ≤ 60 dB | ||||||||
Module dimensions (mm) W x D x H | 482 x 590 x 131 | ||||||||
Module weight | 28 kg / power module,27 kg / charger module,7kg / monitoring module | ||||||||
Communicaitons | SNMP(option) / RS232 / RS485 / USB / dry contacts (standard) | ||||||||
PHYSICAL | UPS dimensions (mm) W x D x H | 600 x 1000 x 1600 | 600 x 1000 x 2000 | ||||||
UPS packaged dimensions (mm) W x D x H | 700 x 1070 x 1760 | 700 x 1070 x 2160 | |||||||
UPS Net / Gross weight (kg) | 225 / 245 | 290/310 | |||||||
input / /output / bypass breaker | Yes | Yes | |||||||
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.