UPS Online Double Conversion 3phase/1phase HT4000(10~20KVA)
Input power factor 0.99 and Active Power Factor Correction (APFC)
(DSP) digital signal processors control technology
Selectable input mode via LCD (3ph/1ph or 1ph/1ph)
Input voltage range from 110 volt to 300 volt
Description
Online Double Conversion uninterrupted power and complete sine waveform in linear and non-linear load at maximum load
Input power factor 0.99 and Active Power Factor Correction (APFC)
(DSP) digital signal processors control technology
Selectable input mode via LCD (3ph/1ph or 1ph/1ph)
Input voltage range from 110 volt to 300 volt
Output power factor 0.9
Flexible battery configuration in UPS (168/180/192/204/216/228/240 settable)
Start without the need for city electricity (Cold Start), settable delayed start when power is restored
Adjust the output frequency at 50 and 60 Hz, Auto Sensing Frequency
Adjust the output Voltage,Selectable battery shutdown voltage (EOD) , automatic start, bypass mode and and ECO mode through the LCD display panel
Standard emergency power off (EPO)
Effective software and hardware protection power-on self-test
Advanced Battery Management (ABM) to control battery charge discharge and fast , stable charge in about three hours , prevention of excessive battery discharge , automatic charging in OFF mode
EMI protection filters and RFI varistor and protection against over current and over voltage, Short-circuit, DC reverse voltage and lightning
Function at relative Humidity between 0 to 95% and temperature between 0 to 40°C, fan speed auto control when temperature varies
Communication with PC by RS232 (standard), USB / RS485 / SNMP / Dry Call (optional)
Swipe left on mobile
MODEL | HT4100 | HT4150 | HT4200 | |||||||||||
POWER | VA | 10000 | 15000 | 20000 | ||||||||||
W | 9000 | 13500 | 18000 | |||||||||||
INPUT | Rated voltage | 3 / 1 | 360 V/380 V/400V/ 415 V | |||||||||||
1 / 1 | 208 V/ 220 V/ 230 V/ 240 V (settable via LCD) | |||||||||||||
Voltage range | 3 / 1 | 190 ~277 V (derating 50%) , 277 ~ 520 V (no derating) | ||||||||||||
1 / 1 | 110 ~160 V (derating 50%) ,160 ~ 300 V (no derating) | |||||||||||||
Frequency | 40 ~ 70 Hz (auto-sense) @ 50/60 Hz ± 5 Hz Bypass | |||||||||||||
Power factor | 0.99 | |||||||||||||
Bypass voltage range | i– 40% ~ +15% (settable) | |||||||||||||
OUTPUT | Rated Voltage | 208 V / 220 V/ 230 V/ 240 V (settable via LCD) | ||||||||||||
Voltage regulation | ± 1% | |||||||||||||
Frequency | Synchronized with utility in mains mode; 50 / 60 HZ | |||||||||||||
Power factor | 0.9 | |||||||||||||
Waveform | Sinusoidal | |||||||||||||
Crest factor | 3:1 | |||||||||||||
Harmonic distortion | ≤ 2% (linear load) ; ≤ 5% (non-linear load) | |||||||||||||
Transfer time | 0 ms | |||||||||||||
Overload Time Transfer to Bypass | 105% ~ 125% : transfer to bypass in 3 mins | |||||||||||||
125% ~ 150% : transfer to bypass in 30 s | ||||||||||||||
BATTERIES | DC voltage | 192 / 240 Vdc @ 12V (support 16/20 PCS) | ||||||||||||
Charging current | 7A | |||||||||||||
Recharge time | 8h | |||||||||||||
SYSTEM | Alarms | Utility failure, Low battery, Overload, UPS fault | ||||||||||||
Protections | Short-circuit, overload, overtemperature, low battery , overvoltage, undervoltage and fan failure | |||||||||||||
Communications | RS232 (standard) / USB,SNMP (optional) | |||||||||||||
Efficency | Mains mode ≥ 92% , Battery mode ≥ 91% , ECO mode ≥ 98% | |||||||||||||
OTHERS | Humidity temperature | 20 ~ 90% RH @ 0 ~ 40°C (non-condensing) | ||||||||||||
IP rating | IP 20 | |||||||||||||
Noise level (1m) | ≤ 58 dB | ≤ 60dB | ||||||||||||
PHYSICAL | Dimensions (W × D × H) (mm) | 260 x 580 x 455 | 262 x 580 x 630 | |||||||||||
Packaged dimensions (W×D×H) (mm) | 350 x 682 x 615 | 360 x 687 x 835 | ||||||||||||
Net weight(kg) | 25 | 39 | ||||||||||||
Gross weight(kg) | 29 | 47 |