1kVA 400Hz to 50Hz/60Hz Frequency Converter
1kVA solid state frequency converter with single phase 115 volt 400Hz input, 0-300V 50Hz/60Hz pure sine wave output, and single or split phase output are available. High-frequency AC converter designed for aircraft testing and maintenance.
Description
1kVA solid state frequency converter with single phase 115 volt 400Hz input, 0-300V 50Hz/60Hz pure sine wave output, and single or split phase output are available. High-frequency AC converter designed for aircraft testing and maintenance.
Affordable price 1kVA frequency converter is an AC power source, that converts 400Hz to 50Hz/60Hz or variable 45-400Hz frequency, 115V input, LED display.
Tips: 400Hz 115V frequency converters Features
400Hz 115V frequency converters are AC power sources integrated with the IGBT/SPWM technology, simple operation but provide cleaner and reliable output voltage and frequency to achieve all kinds of industrial requirements.
- 4 LED display measurements of voltage, current, frequency, and power/PF.
2. Single phase 115 volt 400Hz input and dual output voltage ranges of 0-150V or 0-300V, output frequency of 50Hz/60Hz or 45-400Hz adjustable.
3. Standard RS232 interface, optional RS485 and GPIB interface.
4. High-quality pure sine wave with output power rating from 500VA to 100kVA, which THD less than 1% at resistive load.
5. Comprehensive protection includes over voltage, over current, over load, input under voltage and over temperature with corresponding error codes.
Model | HZ-AFC-110 | |
Input Specifications | ||
Phase | Single phase | |
Voltage | 115V±10% (Please contact us for other input voltage) | |
Frequency | 400Hz±5% | |
Output Specifications | ||
Capacity | 1kVA | |
Phase (Optional)* | Single phase (L, N, G) Spilt phase (L1, L2, N+G; L1+L2=240V, L+N=120V) |
|
Max Current | 0-150V Range | 8.4A |
0-300V Range | 4.2A | |
Voltage | L-N (Line to Neutral) | Low Range 0-150V/ High Range 0-300V |
Transient Response | 30ms | |
Frequency (Optional)* | 45-65Hz Adjustable, 45~400Hz Variable Note: When the output is 400Hz, the load capacity can only reach 50% of the rated capacity; When the output is ≤120Hz, the load capacity can reach 100% of the rated value. |
|
Total Harmonic Distortion (THD) | ≤1% (Resistive Load, Full load 2%) | |
Voltage Regulation | ≤1% | |
Load Regulation | ≤1% (Resistive Load) | |
Frequency Regulation | ≤0.01% | |
Efficiency | ≥85% ( At full load) | |
Protection | Over current, Short circuit, Over temperature, Over load, Phase deficient, Low-voltage protection. | |
Overload Capacity | 100%<Output≤110%, power supply will be automatically cut off after 27min; 110%<Output≤130%, power supply will be automatically cut off after 10s; 130%<Output≤150%, power supply will be automatically cut off after 5s; Output>150%, power supply will be cut off immediately. |
|
Measurement | Current (RMS) | Resolution: 1mA/10mA or 10mA/100mA Accuracy: 0.3%F.S.±3; Counts±0.1%/100Hz |
Voltage (RMS) | Resolution: 0.1V
Accuracy: 0.3% F.S.±2; Counts±0.1%/100Hz
|
|
Frequency | Resolution: 0.01Hz/0.1Hz
Accuracy: 0.3% F.S.±2; Counts±0.05%/100Hz
|
|
Working Environment | ||
Operating Temperature | 0 – 40°C/ 32 – 104°F | |
Relative Humidity | 10-90%,(Non-condensing) | |
Functions | ||
4 Digits LED Display | Voltage, Current, Frequency | |
Interface | RS232 (Optional: RS485, GPIB, just contact us) | |
Memory Function | With power-off memory function, remember the last output parameters automatically. | |
Sync Output Signal | Support | |
Mechanical Specifications | ||
Dimensions (W x H x D) | 430 x 192 x 510mm | |
Weights | 35kg |